Background
The CSIF houses a Zeiss LSM 510 Confocal Laser Scanning Microscope equipped with a Coherent Mira 900 tunable Ti:Sapphire laser for two-photon excitation. The system was installed late January 2001.
Zeiss provides a free, downloadable LSM IMAGE BROWSER capable of opening and coverting Zeiss .LSM files
Unique features of the LSM 510 system include:
Simultaneous collection of single and multiphoton excitation of different fluorophores
Capability to quickly change the settings for lasers and detectors (a single track) using the digital signal processor (DSP). This allows you to scan across a line with one excitation wavelength and back with a second excitation wavelength. No simultaneous detection, no cross talk at all.
Ability to scan ROIs within a sample - circles, rectangles or freehand regions may be specified. Allows FRAP experiments to be performed with maximum precision.
Ability to perform xz scans along curved lines.
To enable two-photon excitation, we have a tunable Ti:Sapphire laser (700 - 1000 nm). The benefits of two-photon excitation include:
- less bleaching of sample
- analysis deeper into the specimen
For an detailed explanation of how the Ti:Sapphire laser is used, go to the MultiPhoton Excitation Microscopy page at the Coherent web site and download the "MPE tutorial."
System specifications
Microscope - Axiovert 200M inverted, fully motorized microscope
Objectives -
| empty |
Name/magnification |
immersion |
NA |
working distance |
DIC |
|
Plan-Neo 10X |
air |
0.30 |
5.6mm |
no |
|
Fluar 20X |
air |
0.75 |
0.66 mm |
yes |
|
Plan-Neo 40X |
oil |
1.3 |
0.17 mm |
yes |
|
C-Apochromat 63X |
water |
1.2 |
0.24 mm |
yes |
|
Plan-Apo 63X |
oil |
1.4 |
|
yes |
|
AchroPlan 63X |
water |
0.9 |
2.2 mm |
no |
|
Plan-Apo 100X |
oil |
1.4 |
|
yes |
|
Fluar 100X strain-free |
oil |
1.3 |
|
yes |
Light sources -
The microscope is equipped with a mercury arc source and filter blocks for DAPI/FITC/Rhodamine for identification of labelled specimens by eye.
The microscope has a transmitted light channel for capturing DIC images in addition to the fluroescent channels. For fluorescent collection, the system has the following lasers with these respective lines:
| empty |
Argon |
458/488/514 nm |
25 mW |
|
HeNe |
543 nm |
1 mW |
|
HeNe |
633 nm |
5 mW |
|
Ti:Sapphire |
700-1000 nm tunable range |
|
Software:
- LSM 510 W.S software, version 3.2
- LSM Flex Scan package
- Physiology software, v 3.2
- Software 3D for LSM, v 3.2
Manual
To obtain a copy of the CSIF user manual for this system, you will need to have Adobe Acrobat reader installed on your computer.
Download a copy of CSIF user manual - LSM 510
Download CSIF server information sheet - explains where data is stored, how long it is stored, and how to ftp from the CSIF computers to your computer.
|